viatalk corporate information
Viatalk Datacenter Info
Owning our own datacenter
allows us to provide you with unmatched reliability and uptime.
Not being dependant on other companies to provide us with access
to the servers, reboot servers, make hardware upgrades on the
fly, and fix problems before they become problems for our customers,
allows us to provide high quality VoIP service to residents
and businesses in the US and Canada. |
 |
Location: 21 Corporate Drive, Clifton Park,
NY
An area not prone to any major natural disasters ensures you that
your servers will not be down as a result of Mother Nature.
Building Size: 52,000+ Sq. Ft.
A new class a office building, 21 corporate drive offers the perfect
location for housing a world class data center.
Data Center Size: 10,000+ Sq. Ft.
Large enough to hold thousands of servers and the ability to more
than double the capacity of the server room ensures you will have
room to grow for years to come.
Connection: Redundant OC-12 Loops through
TW Telecom
Huge pipes with bandwidth available on demand up to OC-12 capacity
ensures that your site will be available fast even during peak usage
hours.
Networking: High end gigabit Ethernet infrastructure
All wiring is done with tested factory terminated cat5e gigabit
Ethernet wiring to ensure maximum bandwidth. Cisco Routers and Switches
ensure that your site will not be down as a result of inferior hardware
failure.
Network Security: DOS and DDOS attack prevention
in place.
High end DOS (Denial Of Service) and DDOS (Distributed Denial Of
Service) attacks are stopped using redundant firewalls.
Cooling: Redundant Rooftop 12 1/2 Ton AC Units
The server room is kept at a cool 65 degrees Fahrenheit and the proper
level of humidity to ensure both condensation and static electricity
will not be a problem no matter what the weather is like outside.
Electrical: Multiple 30 Amp Circuits Per
Rack
Running our electrical circuits at 75% max capacity ensures your
server will never be short on the power it needs no matter what
conditions happen that could affect the power further up the line.
UPS: Full UPS Battery Backup for all equipment
All equipment is backed up using multiple separate APC battery backup
units to add extra redundancy in case of power failure. All UPS
equipment is automatically tested every 2 weeks to ensure working
order.
Generator: Full diesel generator backup for
all equipment
All equipment is on a powerful Kohler diesel power generator which
is turned on automatically 4 seconds after a power failure, long
before the battery backup begins to fade. 1,000 gallons of fuel
are kept on site, with refueling contracts in place.
Staff: 24/7/365 On Site Staff
Full staff means that no matter what time of day or night a problem
may arise, the proper technicians to handle the problem be it software,
hardware, or networking, are available to fix it right away.
The Connections:
Redundant OC-12 fiber loops directly from our network
to Time Warner Telecommunications' nationwide fiber network allows
us to send your site out on any number of different carriers.
|